Please wait...

750 bbl Coated Storage Tank

Listing ID:
ASSK-45549
Published

General Info
Year Built:
2005
Service Type:
N/A
PASC Condition Rating:
C
Connection Status:
Connected
Tank Details
Capacity:
750 bbl
Manufacturer:
Argo
Tank Type:
Storage Tank
Insulated:
Yes
Coated:
Yes
Coating Details:
20.0 – 40.0 mils of Enviroline 376 Epoxy
Double Wall:
No
EnviroVault:
Yes
Serial #:
7366
Heated:
Yes
Elevated:
Yes
Dimensions:
15.5'x24'
Notes:

Tank features:

·       Tank to be built & tested to API 12F Specs. Modified (Non-labeled)

·       Tank diameter:                 15’ – 6”

·       Tank height:                     24’ – 0”

·       Floor:                                1/4” thick.

·       Tank Shell:                       3/16” thick.

·       Roof (1:12 slope)              1/4” thick. (Weak roof to shell joint – Not back welded)

·       Nameplate & bracket.

·       24” x 36” manway c/w manway cover.

·       8” Enardo Std service 330 thief hatch                  Set @ 4 oz. Pressure/0.4 oz. Vacuum.

·       8” thief hatch extension (Argo fabricated).

·       4 – Lift lugs.

·       1 – Tail lug.

·       Caged ladder.

·       4 – Hauling pads.

·       Argo Standard service level gauge system c/w metric level gauge board.

·       (1) Enviro Vault TM  c/w doors.  Pump Out connection and catadyne heater to be located inside of Enviro Vault TM 

 

Nozzles:

·       N1 – 4” 150# RFSO, Std c/ repad                                    Spillover

·       N2 – 3” 150# RFSO, Std c/ dbl flange                             Pump out w/ internal downcomer, ball                                                                                                                                                   valve, camlock connection & dustcap.

·       N3 – 8” 150# RFSO, Std  c/ gooseneck                           Vent

           

Internal Finish:

·       Blast:                    SSPC-SP5 White Metal blast

·       Coating:    20.0 – 40.0 mils of Enviroline 376 Epoxy.

 

External finish:

·       Blast: SSPC-SP7 Brush blast.

·       Insulation: 1-1/2” Spray urethane insulation & finished with two coats of Black Fire Retardant Sealer..

·       Paint: All projection with 1.5 – 2.0 mils of Black Latex.

 

 

CatadyneHeater:

·       CCCI Thermal 24” x 24” Catadyne Heater (16,000 btu/hr input)

·       Natural gas regulators

·       Grill Guard

·       100 % Safety Shut off valve

·       Wired to code with 25’ starter cables (12 VDC)

·       It is assumed that the fuel gas supply will be sweet, dry & 250 Psi maximum.

·       Heat buffer plate

·       3” vent

·       Heater located inside of Enviro Vault TM 

Testing:

·       Tank is to be air/soap leak tested to 8 oz. in accordance with API 12F.

Financial Info
Availability Status
Available
Location
Nearest Town / City
Edmonton
Province
AB
Country
Canada
Share item via

Tanks


There is no category.